 No fans design
 No fans design
 Quick and easy installation
 Quick and easy installation
 High-quality power output and low THDI
 High-quality power output and low THDI
 MPPT efficiency > 99.9%
 MPPT efficiency > 99.9%
 Two MPPT design
 Two MPPT design
 Active and reactive power compensation, adjust power facto
 Active and reactive power compensation, adjust power facto
| 
 | 
 | 
| Inductor external Effectively reduces the internal temperature of the box, greatly improving product reliability and life. | All aluminum chassis design Full curved surface coverage, making the body lighter and effectively resistant to oxidation and acid and alkali corrosion. | 
| 
 | 
 | 
| External WIFI/485/GPRS options Make it easy for users to understand the running status of the machine | Touch button Has high reliability and more sensitive response | 

1. The installation method and position must be suitable for the weight and size of the inverter;
2. The inverter must be installed on a solid wall such as a brick wall or a concrete wall to avoid noise or falling when the inverter is running;
3. The installation site should be clearly visible and can be safely accessed without the use of scaffolding and other auxiliary means;
4. In order to facilitate the installation and operation, the installation height of the inverter should be flush with the eye height;
5. The highest altitude of the installation site shall not exceed 2000m, otherwise the inverter may reduce power operation;
6. To ensure that the inverter runs well, the ambient temperature of the installation site should be between -25 ° C ~ +60 ° C;
7. Do not install the inverter in direct sunlight, so as not to cause the temperature is too high, resulting in inverter power down operation;
8. There should be shielding above the inverter;
9. Sufficient effective space should be left around the inverter for good heat dissipation;
10. Vertical installation, wiring area must be down, not allowed to install horizontally; The tilt angle shall not exceed 30 degrees when installed backward; Tilted forward, horizontal and inverted installation is not allowed.
| PV Input Data | PIS A5 | 
| Max. DC Power ( W ) | 7000 | 
| Max. DC Voltage ( V ) | 600 | 
| MPPT Voltage Range ( V ) | 70-550 | 
| MPPT Full Power Voltage Range ( V ) | 180-550 | 
| Rated Input Voltage ( V ) | 360 | 
| Start-up Voltage ( V ) | 70 | 
| Max. Input Current ( A ) | 14 x 2 | 
| Max. Short Current ( A ) | 18 x 2 | 
| No. of MPP Tracker / No. of PV String | ‘2/2 | 
| Input Connector Type | MC4 | 
| AC Output Data | PIS A5 | 
| Max. Output Power ( VA ) | 5000 | 
| Nominal Output Power ( W ) | 5000 | 
| Max. Output Current ( A ) | 24 | 
| Nominal Output Voltage ( V ) | L/N/PE, 220Vac, 230Vac, 240Vac | 
| Grid Voltage Range | 180Vac-276Vac ( According to local standard ) | 
| Nominal Output Frequency ( Hz ) | 50/60 | 
| Grid Frequency Range | 45-55Hz ( According to local standard ) | 
| Output Power Factor | 1 ( Adjustable from 0.8 leading to 0.8 lagging ) | 
| Output Current THD | <3% | 
| Efficiency | PIS A5 | 
| Max. Efficiency | 98.2% | 
| Euro Efficiency | 97.9% | 
| Protection | PIS A5 | 
| PV Reverse Polarity Protection | YES | 
| PV Insulation Resistance Detection | YES | 
| AC Short Circuit Protection | YES | 
| AC Over Current Protection | YES | 
| AC Over Voltage Protection | YES | 
| Anti-lslanding Protection | YES | 
| Residual Current Detection | YES | 
| Over Temperature Protection | YES | 
| Integrated DC switch | YES | 
| Surge Protection | Integrated ( Type III ) | 
| Smart IV Curve Scaning | YES | 
| Quick Arc Fault Circuit Interruption | Optional | 
| General Data | PIS A5 | 
| Dimensions ( W x H x D, mm ) | 358 x 360 x 142 | 
| Weight ( kg ) | 10 | 
| Protection Degree | IP 65 | 
| Enclosure Materia | Aluminum | 
| Ambient Temperature Range ( °C ) | -25 to 60 | 
| Humidity Range | 0-100% | 
| Topology | Transformerless | 
| Communication Interface | RS485 / WiFi / Wire Ethernet / GPRS ( optional ) | 
| Cooling Concept | Convection | 
| Noise Emission ( db ) | <28 | 
| Night Power Consumption ( W ) | <1 | 
| Max. Operation Altitude ( m ) | 4000 | 
| Certifications and Standards | PIS A5 | 
| EMC Standard | EN/IEC 61000-6-2, EN/1EC 61000-6-3, EN61000-3-2, EN61000-3-3, EN61000-3-11, EN61000-3-12 | 
| Safety Standard | IEC 60068, UL1741, EN62109 | 
| Grid-connection | IEEE1547, CSA C22, EN50549, VDE4105, VDE0126, RD1699, ABNT NBR16149 & 16150, AS4777.2, NB/T32004, G98/G99, IEC6172 | 
| User name | Member Level | Quantity | Specification | Purchase Date | 
|---|
 
	 
		WhatsAppContact
 
 
	Mobile
stations